REPAIRS
Replacing the supply cable
Turn the cooktop over and unhook the
terminal board cover by inserting a
screwdriver into the two hooks “A”.
Open the cable gland by unscrewing
screw “F”, unscrew the terminal screws
and remove the cable.
The new supply cable, of suitable type
and section, is connected to the terminal
board following the diagrams shown
below.
SECTION OF THE SUPPLY CABLES
AND CONNECTION DIAGRAM
The external diameter of the supply
cable must not be more than 9 mm.
Cable section:
230 V ~ 50/60 Hz 3 x 1,5 mm
2
For the FRYER use cables type:
H05VV-F
or H05V2V2-F resistant to 90°C
or H05RN-F
For the BARBECUE use cables
type:
H05RR-F
For the CERAMIC GRIDDLE use
cables type:
H05RR-F
230 V
PE
N
L
1 (L )2
Fig. 6.3
230 V~
Vue de la page 22